What do current clamps and cameras measure?

Choose the source that answers the production question.A CT clamp measures current; a camera counts visible finished parts and tracks downtime.CT clampCameraCurrent signal✓—Finished parts—✓Machine status◐✓Downtime◐✓
Choose the source that answers the production question.

FactoryVision is a working product used in a Turkish door and furniture factory. It counts finished parts, tracks downtime, and shows each station against its daily target. FactoryVision serves countable, discrete parts; the camera needs a suitable view of the work area.

Buying starts with an introductory call. After the call, FactoryVision gets to know your company so the setup fits your machines and processes.

A current clamp measures electrical current without breaking the circuit. The monitoring system then interprets that signal. Before relying on it for production reporting, check how its readings correspond to the machine’s actual running, stopped, and cycle states.

A camera observes what is visible in its field of view. FactoryVision counts finished parts and shows station status. During setup, assess the view for overlapping or clumped parts, stacking, and motion blur.

The choice starts with the information your team needs: an electrical signal from the machine, visible finished output, or both.

When should you use a CT current clamp for machine monitoring?

A current clamp is worth considering when the question is about machine activity and an electrical signal is available for the monitoring system to interpret. Demand evidence records interest in tracking machine cycles without control-panel rewiring and in capturing machine states without changing PLC logic.

A clamp’s current reading is not, by itself, a fault label or a finished-part count. Ask the supplier how the system identifies each state and validate those classifications against the machine’s actual operation. If you intend to use cycles as a production count, check the relationship between cycles and finished parts.

A clamp surrounds a conductor without breaking the circuit. Access to the appropriate conductor and the installation work depend on the machine and the chosen system; confirm them with a qualified electrical professional.

When should you use a camera to count parts?

Check camera view and part visibility at the station.A fixed camera views the machine work area and counts visible finished parts without wiring into the machine.1CameraMachinePartsView area
Check camera view and part visibility at the station.

Vision fits a question about visible output and station progress:

  • **Finished-part counts:** FactoryVision counts visible finished parts.
  • **Station status:** It compares finished work with the station’s daily target. A green light means the station is on track, yellow means the target is at risk, and red means the station is behind.
  • **Station and shift records:** Counts are shown by station and shift and tied to the order at that station.

FactoryVision uses one camera per machine. No sensors are fitted and no wiring goes into the machine. Its counting models run on a small computer in your factory.

FactoryVision serves countable, discrete parts. Continuous processes such as extrusion are outside that scope. During setup, use the live view to check the camera’s angle and focus. A printed marker in view provides real scale in millimetres and lets the system detect camera movement.

Compare the information, not just the hardware

Your questionWhat to ask the supplier
Is the machine running or stopped?How does the system derive and validate each state?
How many finished parts came out?Does the system count finished parts directly, or infer the count from cycles?
Which order and shift does the count belong to?How are counts associated with orders and shifts?
What caused a stop?How are stop causes recorded and reviewed?
What installation is needed?What access, mounting, wiring or PLC changes does this machine require?

A dashboard displays information; it does not fix a production problem by itself. Decide who reviews stops and alerts and who takes action.

How is OEE calculated?

Overall equipment effectiveness (OEE) is **Availability × Performance × Quality**. Before comparing an OEE value, ask where each input comes from and how it is validated.

FactoryVision counts finished parts and tracks downtime. Establish how all three OEE inputs are measured before claiming an OEE figure. FactoryVision is not an ERP, MES or SCADA system.

Sources and claims

ClaimSource
FactoryVision is a working product that factories can buy; it runs in a Turkish door and furniture factoryFounder facts
Finished-part counting, downtime tracking, discrete-part scope, and distinction from ERP, MES and SCADAFounder facts
Introductory call, booking link, and subsequent setup planning around the company’s machines and processesFounder facts
One camera per machine; station lights; counts by station and shift tied to the orderSupplied house-style sample: `count-finished-work-with-one-camera`
No sensors or wiring into the machine; counting models run on a small computer in the factorySupplied house-style sample
Printed marker, real scale, camera-movement detection, live-view checks, and continuous-process exclusionSupplied house-style sample
Ten parts to teach a cycle; setup target under an hour per stationSupplied house-style sample
Interest in CT sensors, machine states and cycles; optical limitations; OEE formula; dashboard and worker-surveillance cautionsDemand evidence: `docs/seo/research-2026-11-12/evidence-fv-demand-2026-11-15.md`
A current clamp surrounds a conductor and measures current without breaking the circuitFluke: Using accessory current clamps

Frequently asked questions

What does a CT current clamp measure?

A CT current clamp measures electrical current without breaking the circuit. A monitoring system interprets that signal to identify machine states.

Can a current clamp count finished parts?

A current reading is not, by itself, a finished-part count. If you intend to use cycles as a production count, check how those cycles relate to finished parts.

What can FactoryVision count?

FactoryVision counts visible finished parts. It serves countable, discrete parts; continuous processes such as extrusion are outside its scope.

Does FactoryVision need wiring into the machine?

FactoryVision uses one camera per machine. No sensors are fitted and no wiring goes into the machine.

What should I check when setting up a camera?

Use the live view to check the camera’s angle and focus. Also assess whether overlapping or clumped parts, stacking, or motion blur affect the view.

FAQ

**Do CT clamps or cameras require changes to my PLC program?** Requirements depend on the system and machine. Ask the CT supplier what access and changes installation requires. FactoryVision uses a camera, with no sensors fitted and no wiring into the machine. **Can a CT clamp count parts?** A clamp measures current. Before using detected cycles as a part count, validate how those cycles relate to finished parts on the machine. FactoryVision counts visible finished parts. **What does FactoryVision need to see?** Countable, discrete parts in a suitable camera view. Assess overlap, clumping, stacking, and motion blur at the station. Continuous processes such as extrusion are outside its scope. **Is FactoryVision intended for worker monitoring?** FactoryVision is presented around machine status and part counts. Discuss camera placement and the monitoring purpose with the team before installation; a camera’s field of view depends on where it is placed. **How does buying start?** Book an introductory call. After the call, FactoryVision gets to know your company so the setup fits your machines and processes. Teaching a cycle uses ten parts; the setup target is under an hour per station.